13.3.3
Aansluiting op de vloer
Pre-Set safety measure!
Close valves for cold and warm
water.
Please comply with local rules
and regulations for electrical
systems in wet and humid rooms.
Bedieningshandleiding AVERO Motion
Building side connections – sanitary - electrical
Warm water connection ½ ", female threading tile-even.
Assemble double-nipple, ball valve, dirt trap and rosette (see
illustration Pos. 1 and Pos. 2 for details).
Cold water connection ½ ", female threading tile-even.
Assemble double-nipple, ball valve, dirt trap and rosette (see
illustration Pos. 1 and Pos. 2 for details).
Floor connection: Socket DN 50 flush with the tiles
Junction box (min. IP X5), 230 V/50 Hz, 2.5 mm².
Fuse protection 16 A. Position according to local codes and
standards
Equalize electrical potential according to local codes and
standards.