eNet radiografische stuureenheid DALI 1-voudig mini
Behaviour after the end of the
disabling function
Behaviour on voltage return
Brightness on voltage return
Switch-off warning
Priority, lock-out protection
Priority, restraint
Priority, wind alarm
82580923
J0082580923
On
Off
no change
Last value
Basic setting: No change
On
Off
Last value
Configured brightness
Basic setting: Off
0...100 %
Basic setting: 100 %
On, Off
Basic setting: Off
0...4
Basic setting: 1
0...4
Basic setting: 2
0...4
Basic setting: 3
9/12
Behaviour of the output when
a block is removed.
Defines the behaviour of the
output after voltage return.
Brightness value, set by the
output after voltage return
(mains voltage). The parame-
ter "Behaviour after voltage
return" must be set to "Confi-
gured brightness".
Note: If the value is above the
set maximum brightness or
below the minimum
brightness, then the system
will switch to the appropriate
limit value.
If the switch-off warning is
active, then, during switch-off,
the systems dims to minimum
brightness within 30 seconds
and only then switches off. If
the parameter "Dim down
ramp" is configured as longer
than 30 s, then the length of
the dim down ramp is applied.
If, during the dim down opera-
tion, another command is
given, e.g. switch on or scene
recall, then the switch-off
warning stops and the com-
mand is executed. A switch-off
command restarts the time for
the switch-off warning.
Note: The set time apply to
operation using radio transmit-
ters. The device is switched
immediately when the Prog
button is pressed.
Specifies the priority for
recalling and removing a sce-
ne of type Lock-out protection
for the channel.
Note: 1 is the highest priority
and 4 the lowest. 0 means no
priority.
Specifies the priority for
recalling and removing a sce-
ne of type Restraint for the
channel.
Specifies the priority for
recalling and removing a sce-
ne of type Wind alarm for the
channel.
28.06.2016