In that case, the tool switches off and can only be restarted
after a certain cooling-down period (approx. 2 minutes). The
overload indicator flashes until the machine has cooled
sufficiently and can be used again. The cooling-down time
depends on the temperature of the motor winding and
ambient temperature.
Safety Clutch
The safety clutch should absorb shock and excessive stress. It is an aid
and not an absolute protection. Therefore you have to handle and drill
carefully. To keep it in good condition, the clutch should slip for a
very short time (max. 2 seconds) in each case only. Slipping for
longer periods destroys the safety clutch. After excessive wearing the
clutch has to be renewed by an authorized service shop.
Care and Maintenance
Before the beginning of the maintenance- or repair works you
have to disconnect plug from the mains.
Repairs may be executed only by appropriately qualified and experienced
personnel.
After every repair, the unit has to be checked by an electrical specialist.
According to its design, the tool requires a minimum of care and
maintenance. However, the following maintenance works and component
checks have to be performed in regular intervals:
Clean the tool after completion of your work. Apply some grease
onto the drilling spindle thread. The ventilation slots must always be
clean and unclogged. Make sure that now water gets into the tool
during cleaning.
After the first 150 hours of operation, the gearing oil must be
changed.
Gearing oil changes bring about an essential increase of the tool's
lifetime.
After approx. 250 hours of operation, the carbon brushes must be
checked and, if necessary, be replaced by an authorized specialist
(use only original carbon brushes).
Once per quarter of a year, an electrical specialist should check the
switch, cable and plug.
25