Electrical Connection
The PLD 182 is made in protection class I. For protection purposes the
machine can only be run with a GFCI. The machine is standard equipped
with a PRCD switch in the cord which allows to connect the unit direct to a
socket.
Attention!
The PRCD protective switch must not lay in water.
!
PRCD protective switches must not be used to switch the tool on
and off.
Before starting your work, check the proper function by
pressing the TEST button.
Prior to putting the tool into operation, check the mains voltage for
conformity with the requirements of the tool's nameplate.
Voltage variations between + 6 % and – 10 % are permissible.
Use only extension cable with sufficient cross-section (min. 2,5 mm
cross-section which is to small could lead to excessive power loss and to
overheating the motor and the cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
The tool includes a start-up speed limiter to prevent fast expulsion fuses
from unindented responding.
Additional Handle
Cross section in sq. mm
1.5
20 m
50 m
For manual drilling, the PLD 182 may be used only
together with its additional handle which comes
with the tools.
Place it on the gearing collar from the front and fix
it by turning the handle in direction of the arrow.
20
2
). A
2.5
40 m
80 m