Download Inhoudsopgave Inhoud Print deze pagina

Ii-B. Description (Multi-Temperature Model); Iii-B. Temperature Setting; Humidity Display (Single-Temperature Model); Lighting Mode - ArteVino Cosy COSYP1T Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

II-b. Description (multi-temperature model)

A
B
C
D
B
L
K
J
I
A

Lighting mode

B
Temperature zone concerned
C
Sensor fault alarm
D
Temperature alarm
E
Access to settings and confirmation key
F
Selection and setting keys

III-b. Temperature setting

Recommended setting range for the lowest temperature: 7 - 9 °C / 45 - 48°F.
Recommended setting range for the highest temperature: 17 - 20 °C / 63 - 68°F .
Press and hold down the
key for 5 secs to start.
1
Press the key for approximately 5 secs
.
The display will start to flash
5 secs
5 sec.
2
Press the
or
keys to set the temperature of the
lower part of the cabinet.
3
Press the
key to confirm.
The display on the right will flash.
13
E
F
G
The tactile keys are very sensitive. There
is no need to apply force, a light touch is
sufficient to register the command.
Remember to remove your finger from
the panel between each press.
H
F
G
Lighting mode access and confirmation key
H
Standby key
I
Highest temperature in the cabinet display
J
Hot circuit operating indicator
K
Cold circuit operating indicator
L
Lowest temperature in the cabinet display
4
Press the
or
keys to set the temperature of the
upper part of the cabinet.
5
Press the
key to confirm.
• For the lowest temperature, the default setting is 8°C / 46°F.
However, the temperature can be set from 6 - 10°C / 43°F.
• For the highest temperature, the default setting is 18°C / 64°F.
However, the temperature can be set from 15 - 20°C / 59 - 68°F.
N.B.:
– To operate correctly, your cabinet must be placed in a room with a
temperature of 12 - 30°C / 54 - 86°F.
– A difference of at least 10°C / 50°F is recommended between the
setting values of the low and high temperatures.
The temperature shown on the display is the actual
temperature inside the cabinet. It is therefore necessary
to wait for your new setting to take effect.
IV. Humidity display (single-temperature model)
Your wine cabinet has a function to measure humidity, allowing you
to see the relative humidity level inside the appliance. The ideal
humidity level is above 50%, ideally 60 - 75%.
2 sec.
2 secs
To display the humidity level inside your cabinet, press and hold
down the
button for 2 seconds
V. Lighting mode
1
Press the
key.
The indicator light of the active mode will flash.
You have 2 setting options for lighting:
Permanent lighting (for mood lighting).
Lighting disabled.

8- Everyday maintenance of your wine cabinet

Your ArteVino wine cabinet is a tried and tested appliance.
Maintenance procedures to carry out every 3 months
Clean the ventilation filter:
1
• Remove the 2 screws from the grill
using a n° 2 Allen wrench
(supplied in the accessories bag).
• Remove the grill, retrieve the filter and place it under water
2
• Allow it to dry then reassemble everything.
Maintenance procedures to carry out once a year
• Unplug and unload the appliance.
• Remove any particles that could block the drainage pipe located inside the cabinet, at
the bottom.
• Clean inside the compartments with water and a gentle cleaning product.
• Rinse thoroughly. Dry with a soft cloth.
• Check the condition of the door seal. Cleaning the seal often proves necessary. Cleaning with unsuitable products will cause premature ageing
of the seals. You should therefore follow these rules: Whenever cleaning the seal, finish by rinsing the seal with clean water. There must be no
cleaning product remaining on the seal. Artevino recommends that you use only a mild soapy solution. If cleaning with this type of solution
proves insufficient, it is possible to use, on a one-off basis, an Ethanol-based solution, but with a concentration of less than 10%, and ensuring
that you rinse the seal with clean water.
If you want to increase the relative humidity level in your cabinet,
pour the equivalent of one glass of water onto the humidity cartridge
positioned on the rack at the base of the cabinet, having first
removed the bottles.
2
Press the
or
keys to select the desired mode.
3
Press the
key to confirm.
Precautions to observe: bright light,
never look directly into the beam.
.
1
2
EN
14

Advertenties

Hoofdstukken

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Cosy cosypmt

Inhoudsopgave