ENGLISH
To go back to the functions without any change press the
MENU button again.
Channel Mode
Press the MENU button until
is shown on the
display.
Press the ENTER button, the display starts blinking.
1ch
Use DOWN and UP button to select the
(1 Channel
4ch
7ch
),
(4 Channel ) or
(7 Channel) mode.
Once the mode is selected, press the ENTER button to
setup
(or automatically return to the main functions without
any change after 8 seconds)
To go back to the functions without any change press the
MENU button again.
Working Mode
Used to set the unit in master or slave mode.
Press the MENU button until
is shown on the
display.
Press the ENTER button, the current working mode
starts blinking in the display
Use the DOWN and UP buttons to select
(master),
(slave in sync with the master) or
(2 light show – slave in anti-sync with the master).
Once the mode is selected, press the ENTER button save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Remarks: when "SL 1" or "SL 2" is selected, some menu options are not available. When only one unit is
used, you should always select master mode.
Show Mode
Used to choose to select one of the preprogrammed shows when used in standalone or master/slave
mode. This menu option is not available when the unit is set to slave mode ("S L 1 " or "S L 2 ")!
Press the MENU button until
is showing on the display.
Press the ENTER button, the current show starts blinking in the display.
Use DOWN and UP buttons to select one of the preprogrammed shows
S hL O
12) or
(slow mode)
Once the right show blinks on the display, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Blackout Mode
Blackout mode: when no DMX-signal is detected, the unit goes in blackout.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to master mode.
This menu option is not available when the unit is set to slave mode ("S L 1 " or "S L 2 ")!
Press the MENU button until
is shown on the display.
Press the ENTER button, the current selection starts blinking in the display.
Use DOWN and UP button to select Y E S (blackout) or n o (no blackout) mode.
Once the mode is selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
JB SYSTEMS
®
OPERATION MANUAL
(show 0) to
5/58
ENGLISH
Display on: display is always on.
Display off: display is off when not used.
Press the MENU button until the display shows
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select
Once the mode is selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
Press the MENU button until
Use the ENTER button to change to the mode
stored after 8 seconds. Or press the ENTER button again return to the mode
To go back to the functions press the MENU button.
Used to show the number of working hours of the unit.
Press the MENU button until
Press the ENTER button to show the number of working hours in the display.
To go back to the functions press the MENU button.
Software version:
Used to show the software version of the unit.
Press the MENU button until
Press the ENTER button to show the software version of the unit.
To go back to the functions press the MENU button.
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation for 1 standalone unit:
(show
Just insert the mains cable. The unit starts working immediately in stand-alone mode.
Remark1: You can connect a CA-8 remote controller to the unit if you want to have more control. Refer to
"how to operate the unit" to learn how to do this.
Remark2: if there's no output, please make sure to set the unit in master mode (see previous chapter)
Electrical installation for two or more units in master/slave:
Connect 2 to maximum 16 units together using good quality balanced microphone cables. Put the first
unit of the chain in master mode, the rest must be set to slave mode (SL1 or SL2). See the previous
chapter for more information.
Make sure that all units are connected to the mains.
Done!
Remark: You can connect a CA-8 remote controller to the master unit if you want to have more control
over the master/slave operation
Electrical installation in DMX-mode:
The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
"daisy chain" your DMX controller and all the connected units with a good quality balanced cable.
Both XLR-3pin and XLR-5pin connectors are used, however XLR-3pin is more popular because these
ORION
JB SYSTEMS
Led Display
.
(display always on) or
Display Inversion
is blinking on the display. (normal display)
(display inversion), the option will be automatically
Fixture Hours
is blinking on the display.
blinks on the display.
6/58
®
OPERATION MANUAL
(display off when not used).
(normal display).
ORION