6/ USING YOUR WINE CABINET FOR THE FIRST TIME
III-A. Description (multi-temperatures model 5059S - 5259S)
A
B
C
D
O
N
A
Lighting mode
B
Door open alarm
C
Temperature zone concerned
D
Fault sensor alarm
E
Temperature alarm
F
Carbon filter alarm
G
Validation and settings access button
H
Selection and adjustment buttons
III-B. Temperature settings
Recommended setting range for the lowest temperature: 7 to 9 °C (45° to 48 °F).
Recommended setting range for the highest temperature: 17 to 20 °C (62° to 68 °F).
Press the
key for 5 s to activate.
1
Press the
key about 5 s.
The display starts to flash.
3
Press the
button to validate.
The right-hand display is flashing.
The value on the display is the actual temperature inside the
cabinet, it is therefore necessary to wait before your new setting
takes effect.
E
F
C
M
L
5 sec.
G
H
I
K
J
I
Lighting mode validation and access button
J
Carbon filter counter log access button
K
Power button
L
Highest cabinet temperature display
M
Hot circuit indicator light
N
Cold circuit indicator light
O
Lowest cabinet temperature display
2
Press the
or
section of the cabinet.
4
Press the
or
of the cabinet
5
Press the
button to validate.
The default setting for the lowest temperature range is 8 °C (46 °F).
•
However, this setting can be adjusted between 5 and 12 °C (41° and
54 °F).
The default setting for the highest temperature range is 18 °C (64 °F).
•
However, this setting can be adjusted between 15 and 22 °C (59° and
72 °F).
WARNING: to operate correctly your cabinet should be located in a
room with a temperature between 12 and 30 °C (54° and 95 °F).
The touch keys are very sensitive. There
is no need to push the keys very hard. A
simple, gentle touch is enough to
register the setting. Think to lift your
finger from the control panel between
each touch.
keys to set the temperature of the lower
keys set the temperature of the upper section
15
GB