Electrolyte
Additional option, ERROR 14 error output:
circulation option
Error detection (air pressure monitoring) is optionally available for electrolyte circulation.
(continued)
The charger multifunction panel displays an error message („Error 14") if electrolyte
circulation fails.
Important! If the electrolyte circulation pump does not have an optional error output:
-
If electrolyte circulation pump does have an optional error output:
-
Charge parameter switching: if electrolyte circulation fails, the charger alone ensures
sufficient mixing of the electrolyte.
N
L
Fig. 7 Electrolyte circulation wiring diagram
(1) Charger
(2) Pump
LocalNet connec-
A standardised 10-pin connection socket is available for the LocalNet option. A remote
tion socket
display or a relay board can be connected to the LocalNet connection socket.
The relay board is used to analyse
Relay board
-
option
-
The analysis lines can be connected to a PLC or a process control system.
The connections for the analysis lines are like no-voltage change-over contacts with a
common root. The following information can be transferred:
-
-
-
-
Connect contacts X7/1 and X7/4 together.
Connect no-voltage contact (relay/normally open contact) to contacts X 7/1 and X 7/4
(1)
X 6/1
X 6/2
4 A
X 6/PE
basic information about the operating status of the charger
the SOC of the connected battery
Battery charging/not charging
Battery 80 % charged
Battery fully charged
Charger is working correctly/charger has output an error message
WARNING! An incorrectly configured data cable can cause serious injury
and damage. The galvanic isolation of the individual contacts is not designed
to provide safe circuit separation. The simultaneous use of low voltage and
mains voltage signals is therefore prohibited.
(2)
(1)
Fig. 8 Electrolyte circulation error output wiring
diagram
11
(2)
X 7/1
X 7/4