eNet
Draadloze dimactor enkelvoudig DIN-rail
6.2 Parameterlijst
Settings window
Device settings
Parameters
Manual commissioning
Settings, channel
Parameters
Manual commissioning
Operating mode
Local Operation
Manual switch-off of the run-
on time
Switch-on brightness
32581602
10499444
Setting options, Basic set-
ting
On, Off
Basic setting: On
Setting options, Basic set-
ting
On, Off
Basic setting: On
Normal operation
Continuous on
Continuous off
Basic setting: Normal Operati-
on
On, Off
Basic setting: On
On, Off
Basic setting: Off
1...100 %
Basic setting: 100 %
12.03.2014
Explanations
Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.
Explanations
Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.
Normal operation
The output can be operated
with radio transmitters and the
Prog button.
Continuous on
The output switches to conti-
nuously "On". All operations of
radio transmitters and the
Prog button are ignored.
Continuous off
The output switches to conti-
nuously "Off". All operations of
radio transmitters and the
Prog button are ignored.
Blocks the output for operation
using the Prog button.
Allows manual switch-off of a
running run-on time. If the
parameter is switched off, then
a switch-off command will also
switch the actuator on. This
parameter is directly connec-
ted to the "Run-on time" para-
meter.
During brief operation, the out-
put switches on at the set
switch-on brightness.
Note: If the value is above the
set maximum brightness or
below the minimum
brightness, then the system
will switch to the appropriate
limit value.
9/16