eNet
Draadloze dimactor enkelvoudig DIN-rail
Priority, lock-out protection
Priority, restraint
Priority, wind alarm
Priority, sun protection
Priority, twilight
Switch off brightness overs-
hoot
Switch on brightness unders-
hoot
Minimum brightness
32581602
10499444
0...4
Basic setting: 1
0...4
Basic setting: 2
0...4
Basic setting: 3
0...4
Basic setting: 0
0...4
Basic setting: 0
On, Off
Basic setting: On
On, Off
Basic setting: Off
1...67 %
Basic setting: 5 %
12.03.2014
Specifies the priority for
recalling and removing a sce-
ne of type Lock-out protection
for the channel.
Note: 1 is the highest priority
and 4 the lowest. 0 means no
priority.
Specifies the priority for
recalling and removing a sce-
ne of type Forced position for
the channel.
Specifies the priority for
recalling and removing a sce-
ne of type Wind alarm for the
channel.
Specifies the priority for
recalling and removing a sce-
ne of type Sun protection for
the channel.
Specifies the priority for
recalling and removing a sce-
ne of type Twilight for the
channel.
Allows automatic switch-off
according to the brightness. If
the parameter is On, then the
light controller switches off
automatically when the
brightness setpoint is greatly
exceeded.
Note: This parameter is not
yet active, as a light controller
has not yet been implemen-
ted.
Allows automatic switch-on
according to the brightness. If
the parameter is On, then the
light controller switches on
automatically when the
brightness setpoint is greatly
undershot. We recommend
only using the parameter in
connection with the parameter
"Switch-off on brightness
overshoot".
Note: This parameter is not
yet active, as a light controller
has not yet been implemen-
ted.
Specifies the minimum setta-
ble brightness.
Note: If parameters or scene
values are set to a level lower
than the minimum brightness,
then the system will dim to
minimum brightness.
12/16