eNet
Draadloze dimactor enkelvoudig DIN-rail
Switch-on delay
Switch-off delay
Dim up ramp
Dim down ramp
Dimming adjustment time
32581602
10499444
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
1...60 s
Basic setting: 4 s
12.03.2014
The load switches on after a
delay. Repeated switch-on
commands restart the delay
time. If the load has not yet
been switched on due to the
delay when a switch-off com-
mand comes, then the load
will remain off.
Note: The set time apply to
operation using radio transmit-
ters. The device is switched
immediately when the Prog
button is pressed.
The load switches off after a
delay. Repeated switch-off
commands restart the delay
time. If the load has not yet
been switched off due to the
delay when a switch-on com-
mand comes, then the load
will remain on.
Note: The set time apply to
operation using radio transmit-
ters. The device is switched
immediately when the Prog
button is pressed.
Time between switch-on and
reaching switch-on brightness.
The light is switched on at
minimum brightness and then
dimmed to the switch-on
brightness.
Only applies to switch-on with
transmitters (short operation).
If scenes are recalled or swit-
ching uses logic modules, the
switch-on brightness is appro-
ached using so-called soft
dimming (not configurable).
Time until reaching minimum
brightness. The light is dim-
med to minimum brightness
and then switched off.
Only applies to switch-off with
transmitters (short operation).
If scenes are recalled or swit-
ching uses logic modules, the
system switches off directly.
Time from minimum
brightness until reaching maxi-
mum brightness (dimming
speed).
10/16