Download Print deze pagina

Novy Easy 80 Pro Gebruiksaanwijzing pagina 135

Verberg thumbnails Zie ook voor Easy 80 Pro:

Advertenties

Beschikbare talen

Beschikbare talen

7.2
Recirculation filter replacement indicator
(1861 only)
The Monoblock filter should be changed after 450
hours of cooking. This is automatically indicated by
the appliance. After 450 hours of cooking, odF 00h
will appear on the timer display.
Recirculation filter remaining time
Press the zone selection button of the
extractor.
Press 2x
button of the extractor.
The remaining time is indicated.
Resetting the recirculation filter
indicator
Press the zone selection button of the
extractor.
Press 2x
button of the extractor.
Press 00h for 3 seconds until it changes
to 450 .
Then press 450 again for 3 seconds to
confirm.
Follow the replacement instructions set out
in the chapter Cleaning and Maintenance.
Recirculation filter
above the zone selection
above the zone selection
– 135 –