General
The water heater consists of a steel vessel, with a cop-
per lining to protect against corrosion.
The heater is designed and manufactured for a maxi-
mum cut-off pressure of 9 bar.
Maximum permitted temperature is 95°C.
The EKS 1000 is insulated with 50 mm thick poly-
urethane. The insulation can be removed to make it
easier for the heater to pass through doorways, for
example.
The outer shell is grey plastic.
On EKS 1000, the top insulation must be removed to
provide access to the lifting eyes.
The enclosed kit contains cover discs and a drain valve.
Installation
The water heater must be installed in an upright posi-
tion. The four feet are height-adjustable.
Fit the supplied cover discs before pipe installation. The
cover discs, with self-adhesive backs, must be fitted on
the relevant connection by pushing them over the con-
nections.
All connections (including those not used) must be insu-
lated to minimise idle losses.
INSTALLATION AND MAINTENANCE INSTRUCTIONS
EKS 1000
WITHOUT IMMERSION HEATER CONNECTIONS

Removing the insulation

The insulation on EKS 1000 can be removed, to facilitate
work in confined spaces (the heater's diameter without
insulation is Ø 870 mm).
1.
Remove all screws along the joining plates.
2.
Lift off the top cover.
3.
Pull the insulated jacket halves straight off.
Carry out assembly in reverse order. If the screws are
difficult to fit in the old holes, the plate can be turned
upside down, which produces new holes in the insu-
lated jacket halves.
EKS 1000
Ø 960
mm with insulation
Ø 870 mm without insulation
5