MALFUNCTIONS
SYMPTOM
Burner
extinguishes out
after igniting.
Where the GAD type examination certificates of KIWA refer to the appliance
category "I2EK" this is understood as:
This appliance was configured for the appliance category K (I2K) and is suitable for
the use of G and G+ distribution gases according to the specifications as included in
the NTA 8837:2012 Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0 °C,
upper value) or 41.23 – 42.98 (dry, 15 °C, upper value).
This appliance can moreover be converted and/or again be calibrated for the
appliance category E (I2E) This therefore implies that the appliance: "is suitable for
G+ gas and H gas or is demonstrably suitable for G+ gas and can demonstrably be
made suitable for H gas" within the meaning of the "Dutch Decree of 10 May 2016
regarding amendment of the Dutch Gas Appliances Decree...."
POSSIBLE CAUSE
You did not press the
control knob long and/or
deep enough (at least 3
seconds).
Thermocouple (3) is dirty.
SOLUTION
Keep the control knob fully pressed for
at least 3 seconds between high and low
settings. This can be longer the first time,
because of the supply of gas.
Clean/dry the thermocouple.
EN 7