Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
!
injuries.
The product may only be used for bathing, hygienic and body cleaning
!
purposes.
The arm of the shower head is intended only to hold the shower head. Do not
!
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
!
must not use this product without proper supervision. Persons under the influence
of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
!
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
!
installed.
The hot and cold supplies must be of equal pressures.
!
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of
installation height will also change the minimum height, and that the altered
mounting dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The premounted filter insert must be used to ensure a normal flow of the shower
and to prevent dirt from entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower. Hansgrohe will not be held
liable for this type of damage.
• The product is not designed to be used with steam baths!
• If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
• If the continuous water heater causes any problems, or you have different water
pressures you must install a water limiter to the cold supply, (ordered separate-
ly,article number 97510000).
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
4
English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Centre distance:
Connections G 1/2:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
The desired maximum temperature for example max. 42°C can be pre-set thanks to
the safety function.
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
• The check valves must be checked regularly according to EN 806-5 in accord-
ance with national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary from time to
time to turn the thermostat from total hot to total cold.
Special accessories (order as an extra)
To empty the overhead shower after use, hold it in a slightly inclined position.
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
Assembly (see page 6)
Do not use silicone containing acetic acid!
Safety Function (see page 8)
Adjustment (see page 7)
Maintenance (see page 9)
Dimensions (see page 10)
Flow diagram (see page 10)
Spare parts (see page 11)
tile-matching-disk Colors #95239000 (see page 11)
Cleaning (see page 12)
Operation (see page 14)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 °C to 60 °C
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
max. 1 MPa
0,12 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
150±12 mm
cold right - hot left
70°C / 4 min