Overvoltage category III for measuring in building installation (e.g. outlets or
CAT III
sub-distribution). This category also covers all smaller categories (e.g. CAT II for
measuring electronic devices).
Ground potential
The symbol can be found when you are to be given tips and information on operation.

3. Intended Use

Measuring and displaying electric parameters in the range of excess voltage category III (up to
max. 600 V against ground potential, pursuant to EN 61010-1) and all lower categories.
• Measuring direct and alternating voltage up to a maximum of 600 V
• Measuring of resistance up to 20 MΩ
• Acoustic continuity check
• Diode test
• Non-contact 230 V/AC voltage test
• Electric current measurement (10 A, mA µA, VC155 only)
• K-type temperature measurement (VC155 only)
The two measuring inputs are secured against overload. The voltage in the measuring circuit
may not exceed 600 V. The measuring ranges are equipped with ceramic high-performance
fuses.
The device may only be operated with a 9 V block battery.
The measuring instrument must not be operated when it is open, i.e. with an open battery
compartment or when the battery compartment cover is missing. Measuring in damp rooms or
under unfavourable ambient conditions is not admissible.
For safety reasons, when measuring only use measuring cables or accessories which are
adjusted to the specifications of the multimeter.