NOTICE
Be aware to locate the holes of the
ground plate in between the cable slots as shown
in the image.
D.8 Pull the power cable through the ground plate.
Mount the ground plate of the centre post to the
surface by placing the chemical anchors according
to their instructions.
D.9 Check if the first basic post ground plate is
placed exactly in the right position according to
step D.3 and D.5. Make sure the ground plate is
placed level in all directions. Hold the basic post
ground plate in position while drilling 6 holes.
E. INSTALLATION
CAUTION Work with at least two people when
installing the Memo.
CAUTION The people installing the product
should wear the required protection and clothing.
E.1 Overview of posts locations.
CAUTION Be aware that all basic posts are
labelled. They should be connected to the master
post in the right order, based on their position in
the playing field.
E.2 Lay down the first basic post (2) next to the
corresponding ground plate. Run the cable through
the ground plate, towards the centre ground plate.
WARNING Electric shock risk! Although the
main power supply is not used yet, touching the
uncoated parts of the wire could lead to an electric
shock already. If necessary, only touch the coated
parts of the main power supply.
E.3 Place the basic post on the ground plate,
making sure the slanted top of the post is pointed
towards the centre of the Memo. Pull the cable
further through the tube while placing the post.
Mount the post onto the ground plate using a
thread locker (e.g. Loctite).
E.4 Repeat step E.2 and E.3 for the remaining basic
posts (3-7).
E.5 Place the master post next to the centre
ground plate. Unscrew and remove the lid from the
post.
E.6 Make sure the master post is positioned in the
correct direction.
E.7 Lift the master post above the centre ground
plate. Pull the cables through the bottom of the
D.10 Mount the first basic post ground plate to the
ground by placing the chemical anchors according
to their instructions.
D.11 Repeat step D.9 and D.10 for the remaining
basic post ground plates. Check the position and
level of each ground plate before drilling the holes.
D.12 Fill the slots with concrete and wait until it
has hardened.
NOTICE
You can now continue the installation
by following the steps in chapter E. At the end of
chapter E the flooring will be placed.
post. Lower the post onto the centre ground plate.
Mount the post to the centre ground plate using a
thread locker (e.g. Loctite).
WARNING Electric shock risk! Although the
power supply is not used yet, touching the
uncoated parts of the wire could lead to an electric
shock already. If necessary, only touch the coated
parts of the power supply.
E.8 Connect the power supply cable to the power
terminal.
WARNING Electric shock risk! Touching the
uncoated parts of the wire could lead to an electric
shock. Only touch the coated parts of the power
supply.
WARNING Installation should be done by a
certified installer according to local regulations on
electrical safety (e.g. NEN 1010).
NOTICE
Make sure to connect the positive and
negative pole correctly.
E.9 Connect the basic post cables to the computer
in the master post.
NOTICE
Make sure to connect the right basic
posts to the right input channels of the computer,
based on their labels.
E.10 Place the lid of the post back in place and
mount it.
E.11 Initialize the product:
• Power the product, the green light around the
button lights up
• Hold the button until the first post lights up
and shows its ID, then release the button
61