EN
11.1 Electrical connection
− Protection against the parts under tension must be
ensured after the buildingin.
− The data of connection necessary are on the stickers
place on the hob casing near the connection box.
− The connection to the main must be made using
an earthed plug or via an omnipolar circuit breaking
device with a contact opening of at least 3 mm.
− The electrical circuit must be separated from the
network by adapted devices, for example: circuit
breakers, fuses or contactors.
− If the appliance is not fitted with an accessible plug,
disconnecting means must be incorporated in the
fixed installation, in accordance with the installation
regulations.
− The inlet hose must be positioned so that it does
not touch any of the hot parts of the hob or oven.
Caution! This appliance has only to be
connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
The installation and connection to the
electrical mains may only be entrusted to a
professional (electrician) who is familiar with
the prescribed standards.
– 126 –