MODEL
Cooling capacity
Max. power usage
Air displacement max.
Connected power
Noise level
Cooling fluid
Class of insulation
Fan settings
Operating temperature
Waste pipe
Fuse
Net weight
Dimensions
Safety Warnings
Read all safety warnings and other instructions. Failure to follow all
instructions can cause injury or material damage.
General safety warnings
This unit is exclusively intended for household use.
Always ensure (even during transport!) that the unit remains upright.
If the unit has been lying on its side, wait 2 hours before using. This
time is required in order for the compressor to function correctly.
Ensure that the unit is always placed on a sturdy, flat and horizontal
surface.
Ensure that the unit has a free space of at least 30 cm on each side.
EN
EUROM PAC 7.2
7000 BTU/hour
2050 Watt
785 Watt
R290/140g
Ø 150 mm x 1500 mm
18 kg
33 28 x 68 cm (lxwxh)
EUROM PAC 9.2
9000 BTU/hour
320 m³ / hour
220–240V / 50Hz
65dB(A)
IP20
2
18 - 35°C
F, 250V AC, 2A
2600 Watt
1000 Watt
R290/160g
19 kg.