4 Miscellaneous
GB
•
4.1
Clean-
•
ing and
mainte-
•
nance
•
The filter element contains ceramic balls in-
4.2
Cleaning
side. Rinse under running, warm water. If you
the filter
have not used the device for a long time, you
can also remove the balls, rinse them individu-
ally, let it dry well and reinsert them afterwards.
The filter cartridge can be unscrewed (in an-
ti-clockwise direction) from the tank cap and
may be replaced then.
Depending on the water used, the cartridge
should be replaced at the latest after 6 months.
4.3
Any limescale residue may be removed using a descaler (citric acid) :
1. Remove the filter.
De-
scaling
2. Use the descaler according to the manufacturer's instructions.
3. Pour a small amount into the tank chamber and leave for a few min-
4. Pour out the descaler and rinse several times with clear water.
4.4
This product must not be disposed of together with domestic waste. All
Dis-
users are obliged to hand in all electrical or electronic devices, regardless
posal
of whether or not they contain toxic substances, at a municipal or commer-
cial collection point so that they can be disposed of in an environmentally
acceptable manner. Consult your municipal authority or your dealer for in-
formation about disposal.
Please remove the battery before disposing of the device/unit. Do not dis-
pose of old batteries with your household waste, but at a battery collection
station at a recycling site or in a shop.
22
Pay attention, that mains cable and plug are not contaminated by dust
or dirt to avoid electrical disturbances.
If you do not intend to use the unit for an extended period of time,
empty any remaining water from the tank
Store the unit in a cool, dry place, preferably in its original packaging.
Remove cap from underside of the water tank and store separately to
prevent sleeve gasket from sticking.
utes to take effect.
CAUTION! Water must not get into the air vent
there is no more descaler left inside the appliance.
4
and dry off the unit.
z
! Take care that