VISTUS-VD | ENGLISH
OPERATION (as door intercom system)
1. Press the bell button.
2. The stored ring tone will play on the corresponding indoor station(s)
and the screen will show the image of the outdoor station.
3. Accept the conversation on the indoor unit by pressing briefly on the
talk button ( ).
4. If an external camera is connected to the outdoor station then you
can switch to it by briefly pressing the 'monitor' ( ) button. Press
on the
button again to switch back to the internal camera.
5. If a door opener is connection then you can activate it by briefly
pressing the door opener button ( ). The bell button will light
green for the duration of the door opener as confirmation.
6. Press the talk button ( ) briefly in order to switch the system back
to standby operation.
Note: If a floor button is connected then an unchangeable ring tone
is played when the floor button is activated. This ring tone is fixed
and is not included in the 'normal' tones/melodies to make it easy to
differentiate.
OPERATION (as internal house intercom)
All indoor units that are connected to the same bell button can also be
used as an internal intercom.
1. Press the internal button
which you wish to reach another indoor station. All the connected
indoor station will ring. No image will be shown.
2. To accept the conversation on one of the other connected indoor
stations you need to briefly press the talk button there (B/C.6).
3. The talk button needs to be pressed briefly on one of the two indoor
stations in order to end the conversation.
Note: It is not possible to set different ring tones for internal and
external calls.
Technical data:
Outdoor station
Operating voltage: 15V DC
Standby power: <0.5W
Camera resolution: 380 TV lines
Camera capture angle: Horizontal 125°; vertical 90°
Connection for door opener: ~ 12V DC, max. 0.9 A
(B/C.7) on the indoor station from
Indoor station (3.5")
Operating voltage: 15V DC
Standby power: <0.5W
Monitor resolution: 320x240px
Bell button illumination: automatic via CDS sensor
Indoor station (7")
Operating voltage: 15V DC
Standby power: <0.5W
Monitor resolution: 480x270px
NOTES
The functionality of the unit can be affected by the influence of strong
static, electrical or high frequency fields (discharging, mobile phones,
radios, microwaves).
Cleaning and maintenance
Always disconnect mains powered units from the mains supply before
cleaning (disconnect the plug). The unit housing can be cleaned using
a soapy soft cloth. Do not use any abrasive materials or chemicals.
Remove dust build-up from ventilation slits using a brush and clean up
using a vacuum cleaner. Do not hold the vacuum cleaner nozzle directly
against the unit.
SAFETY INSTRUCTION
In the event of damage to the housing, connectors, power cables or
isolation shielding, switch off the device immediately and disconnect
from the mains power. ELECTRIC SHOCK – DANGER OF
LOSS OF LIFE. (Unplug the mains connector from the socket!).
Damage should be repaired immediately by a specialist!
Do not take the product apart! There is a danger of lethal
electric shock!
Never carry out repairs yourself!
For reasons of safety and licensing (CE), unauthorised conversion and /
or modification of the product is prohibited.
The design of the product complies with protection class 1. Only a
standard mains socket (230V ~ /50Hz) of the public mains supply may
be used to power the device. Devices powered by mains voltage must
be kept away from children. Please therefore be particularly careful in
the presence of children.
18 18