9.2.2 Restrictor tray

The appliance can be provided with a restrictor tray. This can be used to reduce the draft in the channel. At
delivery, the restrictor tray is located in the fireplace. In case of a duct with a draft that is (too) strong, the restrictor
tray must be installed.
When installing the restrictor tray, proceed as follows (see appendix 2, fig. 5):
Ø
Remove the flame baffle plate (see section 9.7);
Ø
Unscrew the nuts of the flue gas mouth.
The Odin/Oval Front/Tunnel, Fixed is suspended from a pipe. Support the appliance with a lift table or a scissor
!Caution
jack.
Ø
Place the restrictor tray.
During placement, always make sure that the partitions of the restrictor tray are pointing down.
!Caution
Ø
Fasten the restrictor tray with the three bolts/nuts of the discharge pipe or ring.
Ø
Place back the flame baffle plate.

9.2.3 Flue exhaust

The flue exhaust at the Odin has a connection with a 150 mm diameter. The flue exhaust can be connected to the
conical exhaust ring in two ways: dewatering and non-dewatering.
Here, you will have to use the correct connection pieces.
In case of a dewatering connection, other connection pieces are used than in the case of a non-dewatering
!Caution
connection.
The required connection pieces are available via your supplier.
The above-mentioned instructions do not apply to the Odin Front/Tunnel, Fixed. In this type the flue exhaust pipe
!Caution
is a fixed component of the appliance (see section 9.8.2).
The Oval Tunnel first meter of the flue pipe is part of the appliance.