Appendix V: Connector aansluitingen
Connector aansluitingen van de 25-polige Sub-D connector aan de achterzijde van de
generator:
Pin 1
= External Remote HV On/Off + (Plus)
Pin 2
= Remote I Setpoint
Pin 3
= Remote U Setpoint
Pin 4
= Remote U Output
Pin 5
= Remote I Output
Pin 6
= +24 V DC Input Voltage (optioneel, voeding voor fieldbus)
Pin 7
= +12 V DC Output Voltage
Pin 8
= Niet gebruikt
Pin 9
= Limit Alarm OC (Open Collector) / Arc Detect OC (Open Collector)
Pin 10 = Operating OC (Open Collector)
Pin 11 = Niet gebruikt
Pin 12 = Advanced output Control
Pin 13 = Niet gebruikt
Pin 14 = External Remote HV On/Off – (Minus)
Pin 15 = Ground
Pin 16 = Ground
Pin 17 = Ground
Pin 18 = Ground
Pin 19 = Ground
Pin 20 = 0 V (van +12V DC Output Voltage)
Pin 21 = Niet gebruikt
Pin 22 = Limit Alarm OE (Open Emitter) / Arc Detect OE (Open Emitter)
Pin 23 = Operating OE (Open Emitter)
Pin 24 = Ground
Pin 25 = Ground
CM5_UM_9752090318_NL_V1_8
73