6-92 Terminal 42 Digital Output
*[0] No operation
[1] Control ready
[2] Drive ready
[3] Drive ready/remote control
[4] Standby / no warning
[5] Drive running
[6] Running / no warning
[7] Run in range/no warning
[8] Run on ref/no warning
[9] Alarm
[10] Alarm or warning
[12] Out of current range
[13] Below current, low
[14] Above current, high
[21] Thermal warning
[22] Ready, no thermal warning
[23] Remote, ready, no thermal
warning
[24] Ready, Voltage OK
[25] Reverse
[26] Bus OK
[35] External Interlock
[45] Bus Control
[60] Comparator 0
[61] Comparator 1
[62] Comparator 2
[63] Comparator 3
[64] Comparator 4
[65] Comparator 5
[70] Logic rule 0
[71] Logic rule 1
[72] Logic rule 2
[73] Logic rule 3
[74] Logic rule 4
[75] Logic rule 5
[80] SL digital output A
[81] SL digital output B
*[0] Digital and ctrl.word
[1] Digital only
[2] Controlword only
8-02 Control Source
[0] None
*[1] FC Port
8-03 Control Timeout Time
0,1-6500,0 s, * 1,0
8-04 Control Timeout Function
*[0] Off
[1] Freeze output
[2] Stop
[3] Jogging
[4] Max. speed
[5] Stop and trip
[20] N2 Override Release
Tabel 1.29
VLT HVAC Basic Drive Snelgids
Parameterlijst
8-06 Reset Control Word Timeout
*[0] No function
[1] Do reset
8-3* FC Port Settings
8-30 Protocol
*[0] FC
[2] Modbus RTU
[3] Metasys N2
[4] FLN
[5] BACNet
8-31 Address
1-247, * 1
8-32 Baud Rate
[0] 2400 Baud
[1] 4800 Baud
*[2] 9600 Baud
[3] 19200 Baud
[4] 38400 Baud
[5] 57600 Baud
[6] 76800 Baud
[7] 115200 Baud
8-33 Parity / Stop Bits
*[0] Even Parity, 1 Stop Bit
[1] Odd Parity, 1 Stop Bit
[2] No Parity, 1 Stop Bit
[3] No Parity, 2 Stop Bits
8-35 Minimum Response Delay
0,001-0,500 s, * 0,010
8-36 Max Response Delay
0,100-10,000 s, *5,000
8-37 Max Inter-char delay
0,025-0,025 s, * 0,025
8-5* Digital/Bus
8-50 Coasting Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-51 Quick Stop Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-52 DC Brake Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-53 Start Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-54 Reversing Select
[0] Digital input
MG18A310 – VLT® is een gedeponeerd handelsmerk van Danfoss
[1] Bus
[3] In range
[2] Logic AND
[4] On reference
*[3] Logic OR
[7] Out of current range
8-55 Set-up Select
[8] Below I
[0] Digital input
[9] Above I
[1] Bus
[16] Thermal warning
[2] Logic AND
[17] Mains out of range
*[3] Logic OR
[18] Reversing
8-56 Preset Reference Select
[19] Warning
[0] Digital input
[20] Alarm (trip)
[1] Bus
[21] Alarm (trip lock)
[2] Logic AND
[22] Comparator 0
*[3] Logic OR
[23] Comparator 1
8-7* Bacnet
[24] Comparator 2
8-70 BACnet Device Instance
[25] Comparator 3
0-0x400000UL
[26] Logic rule 0
* 1
[27] Logic rule 1
8-72 MS/TP Maxmaster
[28] Logic rule 2
0-127, * 127
[29] Logic rule 3
8-73 MS/TP Max Info Frames
[33] Digital input DI18
1-65534, * 1
[34] Digital input DI19
8-74 "I am" Service
[35] Digital input DI27
*[0] Send at power-up
[36] Digital input DI29
[1] Continuously
*[39] Start command
8-75 Initialisation Password
[40] Drive stopped
8-8* FC Port Diagnostics
[41] Reset trip
8-80 Bus Message Count
[42] Auto reset trip
0-65536, * 0
[43] Key Ok
8-81 Bus Error Count
[44] Key Reset
0-65536, * 0
[47] Key Up
8-82 Slave Message Rcvd
[48] Key Down
0-65536, * 0
[50] Comparator 4
8-83 Slave Error Count
[51] Comparator 5
0-65536, * 0
[60] Logic rule 4
8-84 Slave Message Sent
[83] Broken belt
0-65536, * 0
13-02 Stop Event
8-85 Slave Timeout Errors
Zie par. 13-02, *[40] Drive stopped
0-65536, * 0
13-03 Reset SLC
8-88 Reset FC port Diagnostics
*[0] Do not reset
*[0] Do not reset
[1] Reset SLC
[1] Reset counter
13-1* Comparators
8-9* Bus Feedback
13-10 Comparator Operand
8-94 Bus feedback 1
*[0] Disabled
-32768-32767, * 0
[1] Reference
13-** Smart Logic
[2] Feedback
13-0* SLC Settings
[3] Motor speed
13-00 SL Controller Mode
[4] Motor current
*[0] Off
[6] Motor power
[1] On
[7] Motor voltage
13-01 Start Event
[8] DC-link voltage
[0] False
[12] Analog input AI53
[1] True
[13] Analog input AI54
[2] Running
[20] Alarm number
[30] Counter A
[31] Counter B
1
low
high
31
1