Download Inhoudsopgave Inhoud Print deze pagina

VOLTCRAFT VC-585 Gebruiksaanwijzing pagina 52

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Frequency "Hz" (electronic)
Range
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
999.9 kHz
1.000 MHz
Signal level:
≤100 kHz: 100 mVrms - 20 Vrms
>100 kHz to 1 MHz: 200 mVrms – 20 Vrms
Pulse ratio "%"
Range
0.1 – 99.9 %
Frequency range: ≤100 kHz
Display of the positive half-wave in %
Diode test
Test voltage
approx. 3.6 V
Overload protection: 600 V
The output current is calculated according to the following formula:
Current = test voltage / resistance
The resistance results from the total of internal PTC (1.5 kOhm) and the resistance of the tested diode
Acoustic continuity tester
Test voltage
approx. 3 V
Overload protection: 600 V, measurement range max. 400 Ω;
Permanent sound <30 Ω, no sound >60 Ω, undefined range >30 to <60 Ω
The output current is calculated according to the following formula:
Current = test voltage / resistance
The resistance results from the total of internal PTC (1.5 kOhm) and measured resistance section
52
Resolution
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.001 MHz
Resolution
0.1 %
Accuracy
±(0.1% + 5)
Accuracy
Not specified
Resolution
0.001 V
Resolution
0.1 Ω

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

1461483

Inhoudsopgave