Download Inhoudsopgave Inhoud Print deze pagina

Continuity Test; Battery Test - VOLTCRAFT VC2030A Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

f) Continuity Test
Make sure that all circuit parts, circuits and components and other objects of
measurement are disconnected from the voltage and discharged.
• Connect the black measuring line to the COM socket "8" and
the red one to the socket V, Ω,
• Set the adjustment wheel "4" to the area
"5" to "DC,
, Ω"
• Connect the two measuring prods with the object to be
measured
• A resistance value up to 40 Ohm will cause a signal to sound
g) Battery Test
• In order to test the capacity of a battery, connect the black measurement line to the COM
plug "8" and the red line to the plug "V, Ω."
• Set adjustment wheel "4" according to the battery type, to
1.5 v. or 9 v., and switch "5" to "DC".
• Place the red measuring tip on the plus pole and the
black measuring tip on the minus pole of the battery.
• The currently measured capacity can be read on the
scale display under the following values
BAT
REPLACE
GODD
36
, "7".
, and the slider
The battery is defective
The battery should be exchanged soon
The battery has adequate reserves
DC
V
AC
DC
AC
DC
V
AC
DC
AC

Advertenties

Inhoudsopgave
loading

Inhoudsopgave