RS-232C Protocol
RS232 Setting
Baud rate:
Parity
check:
Data bit:
Stop bit:
Flow Con-
trol
Minimum delay for next command: 1ms
Control Command Structure
HEX
ASCII
Operation Command
Note:
XX=00-98, projector's ID, XX=99 is for all projectors
Return Result P=Pass / F=Fail
n: 0:Disable/1: Enable/Value(0~9999)
ASCII
VXXS0001
Power On
VXXS0002
Power Off
VXXS0003
Resync
VXXG0004
Get Lamp Hours
VXXS0006
System Reset
VXXG0007
Get System Status
VXXG0008
Get F/W Version
ASCII
VXXG0101
Get Brightness
VXXS0101n
Set Brightness
VXXG0102
Get Contrast
VXXS0102n
Set Contrast
VXXG0103
Get Color
VXXS0103n
Set Color
VXXG0104
Get Tint
VXXS0104n
Set Tint
VXXG0105
Get Sharpness
VXXS0105n
Set Sharpness
All manuals and user guides at all-guides.com
9600
None
8
1
None
Header code
Command code
Command
`V'
Command
Command Group 00
Function
Command Group 01
Function
– 59 –
DLP Beamer – Gebruikershandleiding
AANHANGSEL I
Data code
End code
Data
0Dh
Data
CR
Description
P/F
P/F
P/F
Pn/F
P/F
0:Reset
1:Standby
Pn/F
2:Operation
3:Cooling
Pn/F
Description
n=0~100
Pn/F
n=0~100
P/F
n=0~100
Pn/F
n=0~100
P/F
n=0~100
Pn/F
n=0~100
P/F
n=0~100
Pn/F
n=0~100
P/F
0~31
Pn/F
0~31
P/F
Return Result
Return Value