12. Disposal
Electronic devices are recyclable and should not be disposed of in household waste. Dispose of the
product according to the applicable statutory provisions at the end of its service life.
13. Technical Data
Operating voltage ............................................. 230 V/AC, 50 Hz
Protection class ................................................ I
Protection type .................................................. IPX8
Nominal power (P1) .......................................... 1100 W
Output power (P2) ............................................ 870 W
Self-priming ...................................................... yes
Overtemperature protection .............................. yes
Running-dry protection ..................................... no
Connection cable .............................................. H07RN-F, 3 x 1 mm², length approx. 10 m
Immersion depth ............................................... max. 7 m
Conveying height .............................................. max. 10.5 m
Conveyed volume ............................................. max. 15500 l/h (depending on the conveyed height)
Conveyor medium ............................................ Fresh water
Grain size/contamination .................................. max. 35 mm
Conveyor agent temperature ............................ max. +35 °C
Connection thread pump .................................. 50,8 mm (1 3/4") IG
Hose connection ............................................... 25.4 mm (1") or 31.75 mm (1 1/4")
Dimensions (Ø x H) .......................................... 165 x 315 mm
Weight .............................................................. approx. 7.1 kg (incl. cable)
23