Electric Meter Which Breaks The Circuit - Atlantic VS 500L Gebruikers- En Installatiehandleiding

Advertenties

Beschikbare talen

Beschikbare talen

EN
Action to take
1. Cut-off the water heater power
(the circuit braker should be in the
OFF position).
1
1
AUTO
AUTO
0
0
2. Take a resistance measurement
at the heater element terminals using
a multimeter (in ohm position).
V.2 Electric meter which breaks the circuit
Action to take
1. Check that the meter only cuts-
out when the water heater starts
heating.
2. If you have Peak/Off-peak hours
pricing,
2.1 Switch to forced operation
from your electrical distribution board.
2.2 Check the position of the
circuit breaker (should be
in the ON position).
V.3 Lukewarm water
Action to take
See page 32, Section III Setting the
temperature.
2.1. Shut off cold water
inlet on the safety
unit.
2.2. Turn on a hot water tap in the
house.
34
Your Water Heater : Troubleshooting guide
Null or infinite value.
Value in ohms > 0.
The meter trips as soon as the
water element circuit breaker is
set to ON.
On a shielded product:
Replace the heater element.
Leave the original thermostat
setting in order to enjoy very
warm water in sufficient quantity.
If water flows the hot water tap,
then one of the house's taps is
faulty.
Replace the faulty tap or consult
a plumber to find the cause of
problem.
Solution
Replace the faulty resistor.
Replace the thermostat.
Solution
Faulty resistor.
Solution
Incorrect thermostat setting.
A tap (mixer) allows cold water into the
hot water circuit.
Cause
Cause
Cause