Installation Manual : Overall assembly diagram
Electrical distribution
board
16 A circuit breaker (for 400V),
day/night switch
and 30 mA differential
INSTALLATION PRECAUTIONS :
• Temperature at the installation point
should be between 4°C and 35°C
• Position the water heater as close as
possible to the water supply rooms
• If the water heater is installed
install a water retention tank
L1
Earth
L2
L3
Tap in a bathroom
for example
24
above a living area,
CAUTION
If your pipes are not made from
copper (PER, multi-layer, etc.),
it is MANDATORY to fit a copper
pipe with a minimum length
of 50 cm (DTU.60.1) and/or
a temperature limiter at your tank's
hot water tank. (see p. 28)
Hot water
Hot water
Dielect.
connect.
Cold water
Cold
outlet
water inlet
È
Siphon
Temp.
limiter