Motorkabel en starteraansluiting naar de klemplaat
8101.160
8101.172
8102.172
8109.282
51 671 00
START RELAY, 1-PHASE
Capacitors
Motor cable
(3/4*
Pump
conductors)
Relay
BU/WH*
22
BN/BK*
21
GNYE/*
20
YE*
19
GC**
18
17
16
15
Float switch
(Optional)
PHASE SHIFTER ON MOTOR CABLE
Motor cable from grid
(4/4* conductors)
L3 GY/WH*
L2 BK/BK*
L1 BN/RD*
GNYE
SCREENED MOTOR CABLE
Screen as ground conductor
(GC)
Pump
Motor cable
L3
GY
L2
BK
L1
BN
T1 WH
T2 WH
T3 WH
T4 WH
Subcab
(S3+3/3+S4)
8101.050/.083/.160/.172 Minex Handleiding voor installatie, bediening en onderhoud
Terminal plate
T2
T1
U/M
V/C
W/A
start run
Terminal
plate
BN
W / A
GY
V / C
BK
U / M
WH
T1
T2
BU
BU
BU
BU/WH*
Thermal
BN/BK*
contact
GNYE/GN*
GC**
Phase shifter
Pump
1 - 0 - 1
Motor cable to pump
(4/4* conductors)
L3
min 20m
W
GY
L3 GY/WH*
L2
V
BK
L2 BK/BK*
L1
U
BN
L1 BN/RD*
GNYE
CONTACTOR UNIT, 3-PHASE, FLOAT SWITCH. EU OVER 400V, US/CDN OVER 250V
GNYE
shrink hose
Motor cable
(4/4*/7*
conductors)
Contactor
L3 GY/WH*
5
L2 BK/BK*
3
L1 BN/RD*
1
GNYE/*
-
YE*
-
OG*
-
-
BU*
FGB
(3+S)
info@pompdirect.nl
Tel. 0294-457712
SYMBOLS AND DENOMINATIONS
BN=Brown
BK=Black
WH=White
OG=Orange
GN=Green
GNYE=Green-Yellow
RD=Red
GY=Grey
BU=Blue
YE=Yellow
*SUBCAB AWG/CSA
**GC= Ground check
CONTACTOR UNIT, 3-PHASE
SMART
Motor cable
F
(4/4*/7*
G
Pump
conductors)
Contactor
H
5 - 6
L3 GY/WH*
BK
3 - 4
L2 BK/BK*
GY
1 - 2
L1 BN/RD*
BN
A1
GNYE/*
A2
A2
YE*
GC**
16
OG*
15
BU*
BU
14
Float switch
13
Optional
BN=500-600V
SMART
RD=380-460V
F
G
Pump
Contactor
H
5 - 6
BK
3 - 4
GY
1 - 2
BN
A1
A2
A2
GC**
16
15
14
13
SUPERVISION RELAY
www.grindexpompen.nl
Installatie
=Terminal plate
=Screen
=Ground
=Functional ground
=Crimp isolation for
cable, if not in use
=Socket - Plug
=Inside pump
Pump
FLOAT SWITCH OPTIONAL
EU: MAX 400V
US/CDN: MAX 250V
Terminal
plate
W / A
BK
V / C
GY
U / M
BN
T1
WH
T2
BU
BU/WH* BN/BK*
BU
Thermal
GNYE/GN*
contact
GC**
Terminal
plate
W / A
BK
V / C
GY
U / M
BN
T1
WH
T2
BU/WH*
BU
BN/BK*
BU
Float switch
Thermal
GNYE/GN*
GC**
contact
WS004778C
23