8.4 Responding to a CO alarm

The following actions are only suggestions only. The actual circumstances
may require different protocols.
If in any doubt, consult a qualified professional to develop a suitable action
plan.
If the carbon monoxide detector/alarm sounds, it is crucial to take immediate and effective
action to ensure your safety and the safety of others. Follow these steps:
1. Immediately close gas valves (if applicable).
2. Open windows to maximize ventilation.
Open all windows and doors to allow fresh air to circulate and reduce the concentration
of CO indoors.
3. Evacuate the Premises.
Do not ignore the alarm. Assume that the alarm indicates dangerous levels of carbon
monoxide.
Immediately evacuate all occupants, including pets.
Move to a location with fresh air, preferably outside the building.
4. Call Emergency Services.
Once you are in a safe location, call emergency services to report the alarm and the po-
tential CO leak.
Do not re-enter the building until it has been declared safe by professionals.
5. Check the CO detector.
If the alarm was found to be false after a professional assessment, ensure the CO de-
tector is correctly installed and is working correctly.

8.5 Product status

Display
Description
Preheating
Product preheats dur-
ing startup.
LCD will countdown
from 120 seconds.
Green indicator: 1x
flash every 2 secs.
Normal operation
Product is in normal
operation.
Green indicator: 1x
flash every 40 secs.
Alarm mode
Beeper sounds 4x
continuously.
Red lights flash.
Screen shows real-
time carbon monoxide
concentration levels.
Overrange
Carbon monoxide
levels have exceeded
the measurable
range.
Wi-Fi pairing
Product is open for
Wi-Fi paring.
Connection to Wi-Fi
network in progress.
See section:
Product
to app pairing [} 7]
7
Display
Description
Test mode
LCD display: 000.
Indicators cycle
through colours:
red → green → yel-
low → red.
Beeper sounds 4x.
Sensor fault
See section:
Troubleshooting
[} 8].
Yellow indicator: 2x
flash every 40 secs.
Beeper sounds 2x
every 40 secs.
Fault appears on
the display.
Battery low voltage
Yellow indicator: 1x
flash every 40 secs.
Beeper sound 1x
every 40 secs.
Battery indicator
shows: empty.
Replace the battery.
End-of-life
Product has reached
the end of service life and
can no longer be used.
LCD shows: END.
Yellow indicator: ON.
Beeper sounds 3x
every 60 secs.
Product is connected to
the Wi-Fi network.

8.6 End of service life

When the end of service light indicator [Yellow: Fault] lights up, remove the
product from use and replace it with a new one.
The service life of this product is approximately 10 years under normal conditions. Make
a note of the installation date.
Regular cleaning and maintenance will help prolong use. See section
maintenance [} 8]
.
9 Carbon monoxide (CO) exposure levels and health effects
Important:
The information provided in this table is for reference purposes only and should not be
used as a substitute for professional medical advice or emergency response guidelines.
CO levels
Description
200 ppm
Maximum concentration a healthy adult can tolerate over 8 hours.
400 ppm
Mild headache, feeling weak in 2-3 hours.
800 ppm
Dizziness, nausea, and cramps within 45 minutes, loss of sensa-
tions in 2 hours, death in 2-3 hours.
1600 ppm
Headache, dizziness, nausea within 20 minutes, death in 1 hour.
3200 ppm
Headache, dizziness, nausea within 5-10 minutes, death in 25-30
minutes.
6400 ppm
Headache, dizziness, nausea within 1-2 minutes, death in 10-15
minutes.
12800 ppm
Death in 1-3 minutes.
10 Application "Smart Life - Smart Living"
Some functions include:
Push notifications: Mobile app alerts when the alarm is triggered.
10.1 Download application
TM
Compatible Android
and iOS apps are available from their respective app stores.
Search for "Smart Life - Smart Living".

10.2 Product to app pairing

Automatic pairing (EZ mode)
To automatically pair the product to the app.
Preconditions:
a
The TUYA mobile app "Smart Life - Smart Living" is installed on your mobile device.
a
Your mobile device is near the product.
a
Bluetooth and app access to location services are enabled on your mobile device.
a
Your mobile device is connected to the Wi-Fi network that the detector should be connec-
ted to.
a
The product is in normal operation. See:
1. Press and hold the TEST button for approximately 5 seconds to open the product for
pairing with the app (EZ Mode).
à
The LED will flash quickly and "PAr" will show on the display.
2. Open the mobile app, the product will automatically show up. Follow the onscreen in-
structions to complete the setup process.
à
You can now control the product using the app.
Manual pairing (AP mode)
Use this method if you fail to link your device to the app using EZ mode.
Preconditions:
a
The TUYA mobile app "Smart Life - Smart Living" is installed on your mobile device.
a
Your mobile device is near the product.
a
Bluetooth and app access to location services are enabled on your mobile device.
a
Your mobile device is connected to the Wi-Fi network that the detector should be connec-
ted to.
a
The product is in normal operation. See:
1. Open the app and select: + → Add Device → Add Manually → Sensors → CO Alarm
→ CO Detector (Wi-Fi).
2. Press and hold the TEST button for approximately 5 seconds to open the product for
pairing with the app (EZ Mode).
à
The LED will flash red quickly and "PAr" will show on the display.
3. Press and hold the TEST button for approximately 5 seconds to enter AP mode.
à
The LED will flash red slowly and "PAr" will show on the display.
4. Follow the onscreen instructions to complete the setup process.
à
You can now control the product using the app.
Cleaning and
Product status
[} 7].
Product status
[} 7].

Advertenties

Inhoudsopgave
loading

Gerelateerde Producten voor Sygonix 3209102

Inhoudsopgave