The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and
ducting kits are optional accessories and have to be ordered, they are not automatically supplied
with the chimney hood.
IN THE EXTRACTION MODE:
a. Place the anti-backflow flats item 8 over the round outlet item 6, the telescopic duct and connect the
ducting 150mm (6 INS) over the round outlet on top of the canopy and secure the connections with
appropriate clamping rings or adhesive tape (Fig. 6).
b. Remove the grease filters (see paragraph Maintenance) Fig. 5 being sure that the connector of the
mains cable is correctly inserted in the socket placed on the sides of the fan. Before fitting the chimney
to the canopy make the electrical connection as described in the section titled ELECTRICAL. When
the electrical connection has been made, test the lights and the fan motor.
c. Each chimney stack consists of two sections. Encase the upper section in the telescopic bottom sec-
tion (Fig. 1 - item 7a & b) by making it exceed at least 150 mm, maintain it in this position with an
adhesive tape (in order to avoid scratches between the 2 sections). Place slightly the chimney on
the canopy and fit the upper sections by expanding the chimneys to allow them to clamp around the
bracket item 2 and secure the chimney stacks to the brackets using the two M4 screws item 12c
provided. Attention scratches risk on the junction line of the canopy with the lower chimney.
Not remove the film from the canopy before the complete fitting of the chimney.
d. Fit the 3 deflectors Item 9.
IN THE RECIRCULATION MODE:
a. Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws (Fig.
2 item 2).
b. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot
and secure the connections with appropriate clamping rings or adhesive tape.
c. Remove the grease filters (see paragraph Maintenance) Fig. 5 being sure that the connector of the
feeding cable is correctly inserted in the socket placed on the side of the fan. Before fitting the chimney
to the canopy make the electrical connection as described in the section titled ELECTRICAL. When
the electrical connection has been made, test the lights and the fan motor.
d. Insert the charcoal filter into the base of the motor housing and secure the filter with two metal secur-
ing straps item A as illustrated in Fig. 4.
e. Each chimney stack consists of two sections. Encase the upper section in the telescopic bottom
section (Fig. 1 - item 7a & b) by making it exceed at least 150 mm, maintain it in this position with
an adhesive tape (in order to avoid scratches between the 2 sections). Place slightly the chimney
on the canopy and fit the upper sections by expanding the chimneys to allow them to clamp around
the bracket item 2 and secure the chimney stacks to the brackets using the two M4 screws item 12c
provided. Attention scratches risk on the junction line of the canopy with the lower chimney.
Not remove the film from the canopy before the complete fitting of the chimney.
f. Fit the 3 deflectors Item 9.
All manuals and user guides at all-guides.com