Technical Data
Type
HB Art #
Nominal voltage
Nominal frequency
Rated power input
Degree of protection
Permissible operation pressure (high/ low) 2.8/ 0.8 Mpa
Max. allowable pressure (high/ low)
Weight net/ gross
Capacity per day
Water tank capacity
Operating temperature
Refrigerant
Application floor area
Noise
Dimension (W x H x D)
Noise
The values given in these instruc-
tions have been measured in ac-
cordance
with
measurement procedure and can
be used to compare appliances.
It may be used for a preliminary as-
sessment of exposure.
Storage
Clean the appliance, the water tank
and the grilles before covering it
with plastic foil.
Store the appliance in a dry and
frost-proof place. Ensure to store
the appliance in a room with a di-
mension of min. 25 - 30 m
appliance shall only be stored in
rooms without permanent ignition
source.
EN
124
a
standardized
. The
3
Barines 30 l
6772531 / 6808916
220-240 V~
50 Hz
540 W
IPX1
3.8/ 1.3 Mpa
17.5 kg/ 19 kg
30 l (30 °C / 80% RH)
5 l
5-32 °C
R290/ 70g
25-30 m
2
46 dB(A)
343 x 512 x 240 mm
Replacement Parts
Warning! Replacement parts
must conform with the re-
quirements specified by the man-
ufacturer. Therefore use original
replacement parts only or spare
parts authorised by the manufac-
turer.
In case of service requests or spare
parts, please contact your local
HORNBACH store or write an email
to: service@hornbach.com