Translation of the original instructions
• Regularly take off the cover and remove
dust with an air gun. Take the opportunity to
have a qualified person check the electrical
connections with an insulated tool.
• Under no circumstances should solvents or
other aggressive cleaning agents be used.
• Clean the device's surfaces with a soft, dry
cloth.
Réglementation :
• The device complies with European Directive.
• The certificate of compliance is available on
our website.
• EAC conformity mark (Eurasian Economic
Commission)
Mise au rebut :
• This product should be disposed of at an
appropriate recycling facility. Do not dispose
of in domestic waste.
GENERAL DESCRIPTION
The chargers ENERGY 124 and 126 are designed to charge lead acid batteries with liquid electrolyte, nominal voltage
from 12V, and with capacity according to the following table:
ENEGRY 124
ENERGY 126
OPERATING MODE WITH TESTER FUNCTION
When it is not connected to the mains supply, this charger is a battery tester. It lets you know the state of the battery.
The integrated voltmeter informs you:
•
<12.3V : battery to be charged
•
between 12.3 and 12.6V : middle charge
•
>12.6V : charged
CONNECTION IN CHARGER FUNCTION
Preliminary precautions
•
For indoor use, with good ventilation.
•
Remove the battery caps if there is, and check the level of liquid. If it is not correct, filled up with distilled water.
Clean well the battery terminals.
•
Check if the battery capacity and voltage are compatible with your charger.
ENERGY 124, 126
Current
Minimum
3A DC
10 Ah
4A DC
15 Ah
EN
Maximum
45 Ah
60 Ah