shapes of pressed wood whose combustion is controlled elec-
tronically.
The fuel tank (A) is located at the rear of the boiler. Filling the
tank is through the back of the lid at the rear of the top.
tion chamber (D).
The ignition of the pellet is via air heated by an electrical he-
ating element (E) and is sucked into the crucible by a smoke
extractor (F)
The combustion air is drawn into the room (where there must
be an air intake) smoke extractor (F).
from the pipe union (G) located in the bottom portion of the
rear of the boiler.
closed at the front by a blind door.
The ash falls under and beside the crucible in which is housed
an ash tray from which the ash must be periodically removed
by vacuuming when cool.
The entire boiler and door are insulated which makes it more
not dissipated in the place of installation but is conveyed only
to the hydraulic system.
The boiler is designed to function with closed expansion tank
pump activation are regulated by the control board which is
equipped with Leonardo
software to achieve high combustion
®
It also has a two-pole socket to connect an external graphic
panel (provided) and/or the Domoklima (the Edilkamin inte-
grated control unit).
The synoptic panel (L) which allows managing and viewing all
A serial port is found at the back of the boliler (cable: code
640560) to be connected to devices that allow remote ignition
Operating modes
The temperature of the water required in the system is set via
manually or automatically modulates the power to maintain or
reach this temperature.
The Eco function can be enabled in small systems (the boiler
shuts down and goes on again according to the water tempera-
ture required).
FEATURES
L
-
D
F
LEONARDO SYSTEM
LEONARDO
allows optimal performance in all conditions thanks to two sen-
sors measuring the pressure level in the combustion chamber
and smoke temperature. The detection of and subsequent opti-
misation of these two parameters is continuous in order to cor-
rect operation anomalies in real time. The LEONARDO
-
The standards for installation must be respected. LEONARDO
system is also able to recognise the type of pellets and automa-
level of combustion.
SERIAL PORT
the rear oh the boiler.
Can be connected via special trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032
battery). Its malfunction is indicated with the following messa-
ges: (not considered a defect but due to normal wear-and-tear):
FUSE * the socket with a switch
on the back of the boiler has two
- 32
-
I
®
®
is a combustion safety and control system which
A
B
E
C
G
P
®
system
-
®
* *