Download Inhoudsopgave Inhoud Print deze pagina

The Couplers Do Not Connect Or Disconnect; The Couplers Do Not Stay Connected - Holmatro EHW 1650 RC Handleiding

Inhoudsopgave

Advertenties

Check the electric cable and the connecting plug for damage. Do not use the pump if the electric
cable is damaged and contact the Holmatro dealer.
Wind the electric cable around the electric motor.
6.4.3
Cleaning and storage
Clean the pump and any accessories before storage.
Clean the hydraulic couplers. Ensure that the dust caps are fitted.
Ensure that the pump cannot tilt or fall over during transport. This may result in leakage of hydraulic
oil.
Dry the unit if it was used in wet conditions. Apply a thin coat of preservative oil to the external steel
parts.
Store the unit horizontally in a dry and well-ventilated area.
7
Troubleshooting
7.1
General
Consult the Holmatro dealer if the listed solutions do not give the desired result, or in case of other
problems. For malfunctions or repair, always specify the model and serial number of the equipment.
7.2

The couplers do not connect or disconnect

/i
Possible cause
There is pressure in the system.
The couplers are dirty on the front.
The tool and/or hose are under pressure.
The pump is under pressure.
The female coupler is faulty.
The couplers are not placed properly in line with
each other for connecting.
The couplers are not properly placed in line with
each other for disconnecting.
7.3

The couplers do not stay connected

/i
Possible cause
The locking mechanism in the female coupler does
not work.
EHW
Solution
Depressurize the system by pressing the "OFF"
button on the pump. Refer to chapter 5.5.
Clean the couplers.
Use the pressure relief tool to release the
pressure. Refer to chapter 5.4.
Depressurize the system by pressing the "OFF"
button on the pump. Refer to chapter 5.5.
Have it repaired by a Holmatro Certified
Technician.
Position both couplers properly in line with each
other and press them together in one smooth
action.
Support and guide the male coupler when
disconnecting.
Solution
Clean the female coupler with clean running
water.
Dry it and treat the inside of the external ring
with preservative oil.
Place and remove the dust cap or male
coupler repeatedly until the external ring
springs back.
916.219.569_003
EN
31

Advertenties

Inhoudsopgave
loading