Download Inhoudsopgave Inhoud Print deze pagina

Operation And Use; Color Screen Wire Controller Interface Introduction; Color Screen Wire Controller Function Introduction - Norsup P13V/32 Gebruiksaanwijzing

Zwembad warmtepomp
Inhoudsopgave

Advertenties

SWIMMING POOL HEAT PUMP TYPE PV
4.

OPERATION AND USE

4.1 COLOR SCREEN WIRE CONTROLLER
INTERFACE INTRODUCTION
(1) Main interface
1
9
2
(2) Button Description
NO.
NAME
NAME
1
ON/OFF
Press to start /shut off the unit
2
Parameter
Click this button to view the unit
state and the parameter
3
CLOCK
Press to set the clock, the timer on
or timer off. When the timer was
starting, the button is green
4
Fault display Click to view fault history
5
Silent
Click to turn on/off silent function
setting
and to set timing Low
speed function
6
MODE
Click to enter mode setting and the
target temp. Setting interface
7
Temp. curve Click to view the temp. and power
curve
8
Water Inlet
Click to enter mode setting and the
Temp.
target temp. Setting interface
9
LOCK
Click to lock the screen. Input "22"
to unlock the screen by press the
"lock button"
16
WWW.NORSUP.EU
3
4
5
6
4.2 COLOR SCREEN WIRE CONTROLLER
FUNCTION INTRODUCTION
(1)
Booting and shutdown
As shown in figure 1.1: In shutdown status, click 1
then the unit will be booted In booting status,
click 1 then the unit will be shut down.
(2)
Mode switch and target temperature Setting
7
(2.1) Mode switch In the main interface, click mode
button or inlet water temperature setting button,
interface displays as follows:
8
Click the refrigeration mode button 1 , automatic
mode button 2 or heating mode button 3 then
you can select the corresponding mode.
(2.2) Target temp. setting
Click the temperature set button 4, you can set
the target temperature.
NOTE
When the unit is designed for single automatic mode
or single thermal mode, the mode can not be switched.
Alterations which serve the technological progress as well as errors excepted!
2
3
4
1

Advertenties