STORAGE
The equipment should be stored in dry, clean conditions away from direct sunlight,
sources of heat, petrol and solvent vapours.
Store the equipment within the temperature range +5°C to +40°C and the humidity
range 0-90%.
TECHNICAL SPECIFICATION
Weight
Head Size Range
Protection Factor
Hum idity 0-90% storage and use (store out of direct sunlight)
Temperature Range
Charging
Use
Storage
Airflow
Initial
Minimum
Power supply
Battery Pack
Battery life
Charging Method/Rate
Battery Charger
Input
Nominal Power Consumption
No Load output
Nominal output voltage @ 4.2 v
IP 20 indoor use only
CE EN 60335-1, 60335-2-29
1.0kg nominal
54 - 61cm
Assigned (APF) 20
+5°C to +40°C
-5°C to +40°C
+5°C to +40°C
210 l\min
150 l\min
3 cell, nominal 3.6V, capacity 3.5 Ah per pack NiMH.
8 hrs (Fully charged battery pack fitted)
Mains charger, 14 hrs from fully discharged
UK 230 ±10% VAC
4W
12VDC
300 mA
24