Safety and operating instructions
For more information please read, Atlas Copco Industrial Power Tools cata-
logue Ordering No. 9837 3000 01.
Handling
Start and operation
When starting the machine both rivet punch/percussive mechanism and throttle
valve must be pushed in.
The throttle valve can alternatively – depending of application type – be oper-
ated before or after the above mentioned step.
For effective vibration damping the mechanism must operate within its free
travel by pushing in the rivet punch together with the percussive mechanism.
Optimal feed force is given under "Declaration of noise and vibration emis-
sion".
Power control
Adjustment can only be carried out when the machine is disconnected from
the air line.
The striking power of riveting hammer can be steplessly controlled by turning
the valve knob. Maximum power is obtained when the pin and the "+"-sign in
the knob is set in its lower position.
Maintenance
Lubrication
When the riveting hammer is in use, it should be oiled once per shift. The oil
(fluid type), which should be applied in an amount of 1 cm
into the air hose. When the machine is in continuous service, installation of an
Atlas Copco oil-fog lubricator is recommended.
An excessive amount of oil will prevent the main valve from functioning. It
is therefore vitally important to lubricate in strict accordance with the rec-
ommendations.
Use lubricants of good quality. The oils and grease delivered by the oil compa-
nies mentioned in the table are examples of lubricants which are recommended.
8
EN
© Atlas Copco Industrial Technique AB - 9836 975300 00
3
, can be dropped
RRH 04P-12