3.19.1 Alarm List

The alarm list provides an overview of active alarms (alarms that are still on). Up to 5 alarms can be displayed.
B alarms: Reset automatically (except where filter timers have been used (not a pressure guard). This must be
reset manually).
A alarms: Must be reset manually (Test I Alarm I History I Reset Alarm).
Alarm point
A_Alarm
B_Alarm
Frost sensor out of range
Supply air sensor out of range
Extract air sensor out of range
Outdoor air sensor out of range
Return water sensor out of range
Frost sensor not connected
Thermostat active
Fire/smoke sensor active
Rotor alarm active
Motor protection active
Water battery frost alarm
Filter alarm
Supply air fi lter alarm
Extract air fi lter alarm
* Here you can choose whether the unit is to stop or continue.
The right to give notice of lack of conformity applies to this product in accordance with the existing terms of sale,
The symbol on the product shows that this product must not be treated as household waste. It must be taken to
By ensuring the correct disposal of the equipment, you will contribute to preventing the negative consequences for the environment and
health that incorrect handling may entail. For further information on recirculation of this product, please contact your local authority, your
Notice of lack of conformity as a result of incorrect or defective installation must be submitted to the installation company responsible. The right to give
notice of lack of conformity may lapse if the system is used incorrectly or maintenance is grossly neglected.
All manuals and user guides at all-guides.com
Input
-
-
Signal B6 <-45°C and
>+50°C
Signal B1 <-45°C and
>+50°C
Signal B3 <-45°C and
>+50°C
Signal B4 <-45°C and
>+50°C
Signal B5 <-45°C and
>+80°C
Signal TA active
Signal BT active
Signal BR active
Signal RA active
Signal TP active
Low return water
temperature
Filter alarm
Signal TFI
Signal FFI
provided that the product is correctly used and maintained. Filters are consumables.
a reception station for recirculation of electric and electronic equipment.
refuse collection company or the company from which you purchased it.
Alarm class Description
Joint alarm (class A alarm active)
Joint alarm (class B alarm active)
A
Temperature sensor in the cross heat exchanger is
out of its measuring range. Sensor fault or sensor
not connected.
A
Temperature is out of its measuring range.
Sensor fault or sensor not connected.
Temperature is out of its measuring range.
Sensor fault or sensor not connected.
A
Temperature is out of its measuring range.
Sensor fault or sensor not connected.
A
Temperature is out of its measuring range.
Sensor fault or sensor not connected.
A
Alarm unless the frost guard for the cross heat
exchanger is connected (applies only to units with
cross heat exchangers)
A
Overheating thermostat has been triggered on
account of excessive temperature in electric
battery
A(*B)
External signal from fi re or smoke detector
B
Alarm from the rotor heat exchanger unit
A
Alarm signal from motor protection. Joint alarm for
the supply air and extract air fans
A
Frost alarm from water battery on account of low
temperature in the water battery
B
Filter replacement alarm (only in units without a
pressure guard)
B
Filter alarm for supply air
B
Filter alarm for extract air