Changing the alarm symbol when using MiniVib
Set the switches on the Baby Alarm as shown in the table below. The Alarm Call/Pager alarm symbol is set
as an Alarm Call on MiniVib.
Setting the microswitches
for symbol selection:
Changing the channel setting
In some cases, it may be necessary to change the channel setting. If two or more users live near one
another, the alarms can interfere. This can be rectified by changing the channel settings so that they are
different for everyone. Any channel can be selected except Channel 0.
If you wish to change channel, set the switches for the Baby Alarm in accordance with the table below.
To change channels on the receiver, see user manual.
Setting the microswitches
for channel selection:
6
All manuals and user guides at all-guides.com
Alarm
Symbol:
Telephone
Door
Fire
Baby
Alarm call/
Pager
Optional
Public alert
Channel:
Switch:
6
7
8
On On Off
On Off On
Off On On
Off Off Off
On Off Off
Off Off On
Off On Off
Switch:
1
2
3
4
0 Off Off On Off Off
1 On Off On Off Off
2 Off On On Off Off
3 On On On Off Off
4 Off Off On On Off
5 On Off On On Off
6 Off On On On Off
7 On On On On Off
8 Off Off On Off On
9 On Off On Off On
A Off On On Off On
B On On On Off On
C Off Off On On On
D On Off On On On
E Off On On On On
F On On On On On
Pre-set alarm symbol
Alarm symbol for use
with MiniVib
5
Common channel
for fire alarm
Pre-set channel
on Baby Alarm
and all receivers

Advertenties