Malfunction
Motor always switching
off.
Motor system does not
switch off by lock up.
Shearing unit is noisy or
vibrates.
Motor gets hot.
Shearing plant cannot
be switched off.
EVO Shearing Plant – Translation of the original instructions
Cause
Cutter blocked.
Mechanical damage in
the shearing handpiece,
in the rigid drive downtu-
be or flexible drive.
Bearing in the shearing
plant faulty.
The belt is slipping.
The belt is slipping.
Bearing faulty.
Bearing faulty.
Ventilation screen dirty.
Malfunctions in the rigid
drive downtube / flexible
drive and / or shearing
handpiece.
Switch faulty.
Rectification
Remove blockage.
For the purposes of fault
finding first of all uncouple
the shearing handpiece
and restart the plant. If the
fault persists, uncouple
the rigid drive downtube
or flexible drive from the
shearing plant. Rectify any
damage.
If the fault still persists,
then have the shearing
plant repaired.
Have the bearing replaced.
Have the belt replaced.
Have the belt replaced.
Have the bearing replaced.
Have the motor replaced.
Clean ventilation screen.
Have fault rectified.
Have the switch replaced.
15