Download Print deze pagina

hajdu HB300 Handleiding Voor Installatie, Gebruik En Onderhoud pagina 47

Warmtepompboiler

Advertenties

____________________________________________EN________________________________________5
The hot water tank should be connected to the electric system only through
permanent connection. It is forbidden to apply any wall socket.
The current of the electric system has to be connected to the hot water tank
through an all-pole disconnection device, which has at least 3mm separation
distance in all poles. This separator equipment must to connect in fixed grid
wiring.
For personnel authorízed to perform the maintanance and change of the electric
wiring system of the appliance to avoid any electrical shock. Only manufacturer
or the authorized service or simmilar skilled budies can do this kind of
maintenence ont he appliance.
2.1.
Summary table of technical data
Sizes: diameter/height/depth
Water pipeline connection
Circulation pipe branch connection
Rated volume
Rated operation pressure
Safety valve max. opening pressure
Largest water supply pressure
Smallest required network pressure
Standby energy use at 60
Weight
Pipe coal connection
Pipe coal heatable volume
Pipe coal surface
Pipe coal flow resistance
Top performance
Durable performance
Durable performance
Type
Air duct connection (inlet/outlet)
Condenser
GWP / Cooling agent / quantity
Max. Power Consumption
Average Power Consumption
Air flow
Reachable static pressure
External static pressure range where the appliance has been
examined
Max. suction side pressure
Max. blow side pressure
Minimum space required for operation (in case of operation without
air duct
Operation temperature range
Max. water temperature
o
COP 15/10-55
C
EN-255-3
EN-16147
COP 7/10-55°C
Noise level
QUALITY CERTIFICATION LABEL-TECHNICAL DATA
Type
o
C
Pipe coal
Heat pump
HB300
Ø661/1930/720
G3/4
G3/4
295 l
0,6 MPa
0,7 MPa
0,525 MPa
0,01 MPa
2500 Wh/24h
124 kg
Rp3/4
-
510 l/the first 10
air (indoor)
Ø190 mm
safety heat exchanger
1300 / R134a / 1100 g
1200W
850W
3
~500m
/h
80 Pa
1013 – 1050 hPa
1,0 MPa
2,5 MPa
3
20 m
o
-7 - +43
C
o
60
C
≥3,5
≥2,1
48 dB(A)
HB300C
287 l
141 kg
287 l
2
1,5 m
130 mbar
minutes
1100 l/h
45 kW

Advertenties

loading

Gerelateerde Producten voor hajdu HB300

Deze handleiding is ook geschikt voor:

Hb300c