2.6
First-time Operation
2.6.1
Function Test
Check the function of the fan for the storage unit by switching on the room temperature regulator.
2.6.2
Charging
The units can be started without initial heating up after the function test. Charging takes place eit-
her manually with the adjuster of the mechanical charging control unit or automatically with the
available Elfamatic charging control unit.
During initial charging, the charging in kWh must be determined and compared with the
maximum permissible charging from the cold state specified in the "Technical Data". The determi-
ned charging may not exceed the maximum permissible charging from the cold state.
During initial charging, a smell may be produced, the room should therefore be adequately aired
(1.5 times air change, e.g. tilted windows). Initial charging in the bedroom should not take place
when sleeping in it if possible.
2.7
Repair, Conversion of Unit
Proceed according to these installation instructions as for the initial installation for re-installation
of a unit which has been dismantled for repairs or which was in operation somewhere else.
In these cases the following must be paid special attention: Parts of the thermal insulation at which
there are visible signs or damage or change which could impair the safety must be replaced by new
parts. The insulation must be tested and the rated consumption measured before commissioning.
2.7.1
Conversion of the Unit
The instructions enclosed with the respective fitting set are applicable for conversions, additions
and installations.
2.8
Transfer
Explain the functions of the unit to the user. Draw his attention to the safety instructions in parti-
cular.
Hand over the operating and installation instructions to the user.
Typ:
WSP 7010
Nr.:
956042710 - 8234
5,25
5,83 6,42 7,00 6,75 7,50 8,24 9,00
5
6
*95604271082340000008*
373
- 000000
3/N/PE ~ 400V 50 HZ
kW
7
8
9
10
h
1/N/PE ~ 230V 50 HZ
2kW
1,7kW
26 W
247611 -34511
Made in Germany
Symbols of the rating plate
(Example WSP 7010)
Total weight
Charging
Discharging
Supplementary heater
Fan
For the Fitter
31