back to optimal voltage range, the power supply is switched back to the starting battery and the air conditioning
compressor is reactivated, turning off the economy function.
Operation with engine off
The device allows the use of the inverter connected to the house battery even when the engine is switched off,
without risk. When the voltage of the house battery drops below 11.1 V during use, the device will switch into
the economy mode. In this mode, the air conditioner fan keeps running, but the compressor is deactivated. This
reduces consumption and protects the batteries from deep discharges. If the house battery voltage continues
to drop, and reaches 10.5 V, the device continues to reduce consumption by completely isolating the inverter
from the batteries. The inverter will only become active again when the house battery voltage reaches normal
operating range, or when power supply from the vehicle alternator is detected.
8
Disposal
Recycling packaging material: Place the packaging material in the appropriate recycling waste bins
wherever possible.
Recycling products with non-replaceable batteries, rechargeable batteries, or light sources:
•
If the product contains any non-replaceable batteries, rechargeable batteries, or light
sources, you don't have to remove them before disposal.
•
If you wish to finally dispose of the product, ask your local recycling center or specialist deal-
er for details about how to do this in accordance with the applicable disposal regulations.
•
The product can be disposed free of charge.