USER MANUAL
AeroFlow® Surface storage heater with FlexiSmart thermostat
to interventions or attempted repairs by persons who have not been
authorised to do so by us. Please note that dismantling of the heater
by the customer or third parties is fundamentally not permissible. If
there is a violation this warranty entitlement shall cease to apply. The
possible replacement of the radiator side part (e.g. when changing the
control technology) and / or the possible shortening of the connecting
cable (e.g. removal of the earthed plug for the purpose of producing
a fixed connection) does not lead to a loss of warranty, insofar as no
intervention in or manipulation of electronic components takes place,
beyond the necessary extent of the modification to be performed, and
the correspondingly permissible work is performed by a qualified expert.
The warranty covers the careful inspection of the radiator or the acces-
sories whereby it must be initially determined whether a warranty claim
applies. In the event of a claim under the warranty we solely decide in
which manner the fault shall be rectified. We are at liberty to replace a
radiator or accessory or to perform a repair. During the warranty period,
we assume all material, assembly and transport costs within the scope
of this warranty.
In addition to the above-mentioned warranty service, the end customer
cannot assert any claims for indirect damage or consequential damage
caused by the device, in particular for compensation for damages incur-
red outside the device. Statutory claims of the customer against us shall
remain unaffected by this clause. Warranty claims must be reported to
us before expiry of the warranty period, within one week of the defect
being detected.
Fixing the wall brackets
3
Guidelines for Installation Distances:
Side walls of the radiator to any masonry: 5 cm
Side walls of the radiator to flammable materials: 10 cm
Distance from radiator to the floor: 8 cm
Distance from the upper radiator boundary to adjacent components or
coverings placed above (e.g., windowsill): flammable 15 cm, non-flam-
mable 10 cm
Only the wall bracket supplied may be used for wall mounting! The
latest regulations according to VDE 0100 part 701 must be complied
with for the installation and operation in damp rooms.The device may
not be mounted directly under a wall socket. In order to avoid excessive
heat radiation upon the wall socket, a certain safety distance must
also be taken into account between the radiator and the wall socket.
This distance is largely determined by the material quality and heat
resistance of the locally installed socket and therefore can not be
assessed by us. We assume no liability for improper handling and
possible damages resulting from this. In case of doubt, consult a
specialist before installation. Suitable screws and dowels must be
used depending on the type and condition of the wall material. When
positioning the wall bracket and the heater, please always observe the
stipulated minimum distances (see the following figures).
Mounting dimensions
10 cm
8 cm
>10cm (non-flammable)
>15cm (flammable)
>5cm (non-flammable)
>10cm (flammable)
>8cm
Measure X
9 cm
Measure Y
9 cm
19 cm
All radiators have four temperature-resistant holders, which guarantee
optimum fixing of the heater. Please note the correct hanging position
of the upper (marking 1) and lower (marking 2) holders on the heater
above
below
With the type-specific dimension table, you can obtain the correct
positioning for the U-rails and the holders for the correct mounting and
fixing of the radiator.
Radiator type
Dim X in cm
Mini 650
Compact 1000/1300
Midi 1500/1950
Maxi 2000/2450
Slim 1200
Slim 1600
Slim 2000
Slim Tall 1600
For the assembly please perform the following steps:
1. The two U-rails must be fixed to the wall whilst observing
the minimum distances and depending on the type-specific
X / Y-dimension.
2. The two holders marked with the number 2 are to be inserted
into the U-rails at the bottom.
3. Following this the radiator is hooked into the lower holders and
tilted forward at an angle. Hold the radiator while doing so!
4. The two holders marked with the number 1 are to be inserted
into the U-rails at the top and temporarily pulled up.
5. Finally, place the radiator in a vertical position and press the
upper holders down until the heater is completely fixed in place.
10
Lamellas
Lamellas
Hanging part
Hanging part
Dim Y in cm
23,2
40,5
46,6
40,5
76,6
40,5
106,6
40,5
76,6
12,0
106,6
12,0
136,6
12,0
23,2
104,0
www.thermotec.ag