Status
One (1) LED quick-flashes red
Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it down for longer than three seconds. The system does not detect a
potential malfunction of the battery due to misuse, for example battery dropped or pierced, external heat damage, etc.
Status
All LEDs show in sequence, followed by one (1) LED showing con-
stantly green.
All LEDs show in sequence, followed by one (1) LED quick-flashing
yellow.
All LEDs show in sequence, followed by one (1) LED showing con-
stantly red.
Technical data
Product generation
Rated voltage
Weight in accordance with EPTA Procedure 01
Pressing time
Max. crimping/pressing force
Storage temperature
Ambient temperature for operation
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a standardized test and can be used to
compare one power tool with another. They can also be used for a preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for different applications, with different
accessory tools, or is poorly maintained, the data can vary. This can significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or when it is running but not actually
being used for a job. This can significantly reduce exposure over the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for example: maintaining the power tool
and accessory tools, keeping the hands warm, organization of work patterns.
Noise values
Sound power level (L
)
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration values
Total vibration (during operation) (a)
Uncertainty (K)
Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶
Before inserting the battery, make sure that the product is switched off.
▶
Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
*2321712*
)
WA
)
pA
)
pA
2321712
Meaning
The Li-ion battery is locked and cannot be used. Consult Hilti Ser-
vice.
Meaning
The battery can remain in use.
The check to ascertain the battery's state of health did not com-
plete. Repeat the procedure, or consult Hilti Service.
If a connected product can still be used, the remaining battery ca-
pacity is below 50 %.
If a connected product can no longer be used, the battery has
reached the end of its useful life and has to be replaced. Consult
Hilti Service.
NPR 32-22
02
21.6 V
2.4 kg
≈ 7 s
32 kN
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
21.6 V
See the end of these operating instructions
−17 ℃ ... 60 ℃
−20 ℃ ... 40 ℃
−10 ℃ ... 45 ℃
77 dB(A)
2.5 dB(A)
69 dB(A)
1.5 dB(A)
< 2.5 m/s²
1.5 m/s²
15