Cleaning the Carriage and Food Grip
1. Disconnect the appliance from the power supply.
2. Lift the food grip from the cradle.
3. Tilt the cradle away from the appliance.
4. Wash with warm soapy water.
5. Dry thoroughly.
Cleaning / Changing the Blade
1. Disconnect the appliance from the power supply.
2. Push the carriage away from the blade.
3. Unscrew and remove the centre plastic cap securing the blade.
4. Carefully lift the blade from the appliance.
5. Wash the blade by wiping from the centre towards the edge.
6. Dry thoroughly.
7. Re-put the blade, ensuring the centre plastic cap is securely tightened.
Note: Caterlite recommend the use of cut-resistant or wire mesh gloves when
cleaning the blade.
Cleaning Behind the Blade
•
With the blade removed use a slightly damp cloth to clean the area behind the blade.
•
Dry thoroughly before replacing the blade.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The unit is not working
The cradle does not move
smoothly along the carriage
Technical Specifications
Note: Due to our continuous improvement process, the product specifications are subject to change
without notice.
Model
Voltage
Power
GH489
230V 50Hz
200W
GH489_ML_A5_v8_20240712.indb 5
GH489_ML_A5_v8_20240712.indb 5
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Food trapped beneath cradle Tilt cradle and clean carriage
Slicing
Blade
Current
Thickness
Diameter
0.65A
1-15 mm
190mm
Solution
Check the unit is plugged in correctly and
switched on
Replace Plug or lead
Replace the plug fuse
Check mains power supply
Max.
Dimensions
Slicing
H x W x D mm
Width
175mm
270 x 362 x 245
EN
Weight
4.1kg
5
2024/7/12 16:04