Translation of the original instructions
STARTPACK TRUCK & STARTPACK TRUCK MOBILE
The unit can not start the vehicle. The
orange LED of the device is flashing.
The unit cannot start the vehicle
anymore and the both LEDs are
switched off.
The charge of the internal batteries does
not start (the charge LED remains green
when first connected to the mains).
The charger red LED flashes during the
charge.
After a day of charge, the end of charge
indicator does not activate.
In external 12V power source mode, the
booster no longer delivers power.
The lamp does not switch on.
BATTERY NOT COVERED BY WARRANTY
Batteries are live parts, their life depends on maintenance. After each use of this starter, it is essential to recharge the
internal batteries. Storage in places with high temperatures greatly reduces the battery charge. In the case of prolonged
non-use, it is strongly recommended to recharge the batteries before use. In general, we recommend leaving the
product plugged in continuously to maintain the batteries at their best performance.
This product is equipped with 2 high performance batteries if the maintenance instructions are not followed the batteries
can deteriorate irreversibly over time.
For this reason the STARTPACK TRUCK batteries are excluded from the warranty.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
• The retractable handle for the mobile version
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
The internal battery is discharged.
Several jump start attempts without
pause between each.
The battery voltage is incorrect..
The voltage of the internal batteries is very
low. It may be that the internal batteries
are damaged.
The internal batteries are damaged and
cannot be recharged.
The fuse has melted.
The cigarette lighter plug is not correctly
plugged to the socket of the machine.
The switch is on OFF or 24V.
The fuse of the cigarette lighter socket
has melted.
The mains switch is on the 24V position
instead of 12V.
The internal batteries are damaged and
cannot be recharged.
The internal batteries are damaged and
cannot be recharged.
The internal thermal protection circuit-
breaker has cut the circuit.
The internal battery is discharged.
Charge the unit, and try again after the charge is
complete.
Wait 3 minutes between 2 starts. Each start
attempt must not exceed 5 seconds.
Check that the voltage of the vehicle's battery
matches with the selected voltage on the unit.
Put the device on charge in order to attempt to
recover the battery.
Contact the GYS after sale service to organise a
replacement of the batteries.
Check and replace the fuse.
Check the cigarette lighter connection.
Set the switch to 12V.
Replace the fuse of the cigarette lighter socket by
unscrewing its end.
Set the switch to the 12V position.
Contact the GYS after sale service to organise a
replacement of the batteries.
Contact the GYS after sale service to organise a
replacement of the batteries.
Disconnect the external device connected to the
machine and wait for the circuit-breaker to reset
itself automatically.
Charge the unit, and try again after the charge is
complete.
EN
15